No. |
Part Name |
Description |
Manufacturer |
14281 |
G901CD-AC12-12 |
Relay. Coil voltage 12 VAC. Mounting PCB w / Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
14282 |
G901CD-AC12-1NIL |
Relay. Coil voltage 12 VAC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
14283 |
G901CD-AC12-NIL2 |
Relay. Coil voltage 12 VAC. Mounting PCB w/Top QC . Contact form C. Covering dust cover. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
14284 |
G901CD-AC12-NILNIL |
Relay. Coil voltage 12 VAC. Mounting PCB w/Top QC. Contact form C. Covering dust cover. Spacing STD UL508. Insulation STD. Class B. |
Global Components & Controls |
14285 |
G901CD-AC220-12 |
Relay. Coil voltage 220 VAC. Mounting PCB w / Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
14286 |
G901CD-AC220-1NIL |
Relay. Coil voltage 220 VAC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
14287 |
G901CD-AC220-NIL2 |
Relay. Coil voltage 220 VAC. Mounting PCB w/Top QC . Contact form C. Covering dust cover. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
14288 |
G901CD-AC220-NILNIL |
Relay. Coil voltage 220 VAC. Mounting PCB w/Top QC. Contact form C. Covering dust cover. Spacing STD UL508. Insulation STD. Class B. |
Global Components & Controls |
14289 |
G901CD-AC24-12 |
Relay. Coil voltage 24 VAC. Mounting PCB w / Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
14290 |
G901CD-AC24-1NIL |
Relay. Coil voltage 24 VAC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
14291 |
G901CD-AC24-NIL2 |
Relay. Coil voltage 24 VAC. Mounting PCB w/Top QC . Contact form C. Covering dust cover. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
14292 |
G901CD-AC24-NILNIL |
Relay. Coil voltage 24 VAC. Mounting PCB w/Top QC. Contact form C. Covering dust cover. Spacing STD UL508. Insulation STD. Class B. |
Global Components & Controls |
14293 |
G901CD-AC48-12 |
Relay. Coil voltage 48 VAC. Mounting PCB w / Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
14294 |
G901CD-AC48-1NIL |
Relay. Coil voltage 48 VAC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
14295 |
G901CD-AC48-NIL2 |
Relay. Coil voltage 48 VAC. Mounting PCB w/Top QC . Contact form C. Covering dust cover. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
14296 |
G901CD-AC48-NILNIL |
Relay. Coil voltage 48 VAC. Mounting PCB w/Top QC. Contact form C. Covering dust cover. Spacing STD UL508. Insulation STD. Class B. |
Global Components & Controls |
14297 |
G901CD-DC110-12 |
Relay. Coil voltage 110 VDC. Mounting PCB w / Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
14298 |
G901CD-DC110-1NIL |
Relay. Coil voltage 110 VDC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
14299 |
G901CD-DC110-NIL2 |
Relay. Coil voltage 110 VDC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
14300 |
G901CD-DC110-NILNIL |
Relay. Coil voltag 110 VDC. Mounting PCB w/Top QC. Contact form C. Covering dust cover. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
14301 |
G901CD-DC12-12 |
Relay. Coil voltage 12 VDC. Mounting PCB w / Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
14302 |
G901CD-DC12-1NIL |
Relay. Coil voltage 12 VDC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
14303 |
G901CD-DC12-NIL2 |
Relay. Coil voltage 12 VDC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
14304 |
G901CD-DC12-NILNIL |
Relay. Coil voltag 12 VDC. Mounting PCB w/Top QC. Contact form C. Covering dust cover. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
14305 |
G901CD-DC15-12 |
Relay. Coil voltage 15 VDC. Mounting PCB w / Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
14306 |
G901CD-DC15-1NIL |
Relay. Coil voltage 15 VDC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
14307 |
G901CD-DC15-NIL2 |
Relay. Coil voltage 15 VDC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
14308 |
G901CD-DC15-NILNIL |
Relay. Coil voltag 15 VDC. Mounting PCB w/Top QC. Contact form C. Covering dust cover. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
14309 |
G901CD-DC18-12 |
Relay. Coil voltage 18 VDC. Mounting PCB w / Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
14310 |
G901CD-DC18-1NIL |
Relay. Coil voltage 18 VDC. Mounting PCB w/ Top QC. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
| | | |