No. |
Part Name |
Description |
Manufacturer |
3571 |
G901AO-DC9-NILNIL |
Relay. Coil voltage 9 VDC. Mounting PCB w/Top QC. Contact form A. Covering open frame. Spacing StdUL508. Insulation STD.classB. |
Global Components & Controls |
3572 |
G901AS-AC110-12 |
Relay. Coil voltage 110 VAC. Mounting PCB w / Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation class F. |
Global Components & Controls |
3573 |
G901AS-AC110-1NIL |
Relay. Coil voltage 110 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
3574 |
G901AS-AC110-NIL2 |
Relay. Coil voltage 110 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
3575 |
G901AS-AC110-NILNIL |
Relay. Coil voltage 110 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation STD. Class B. |
Global Components & Controls |
3576 |
G901AS-AC12-12 |
Relay. Coil voltage 12 VAC. Mounting PCB w / Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation class F. |
Global Components & Controls |
3577 |
G901AS-AC12-1NIL |
Relay. Coil voltage 12 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
3578 |
G901AS-AC12-NIL2 |
Relay. Coil voltage 12 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
3579 |
G901AS-AC12-NILNIL |
Relay. Coil voltage 12 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation STD. Class B. |
Global Components & Controls |
3580 |
G901AS-AC220-12 |
Relay. Coil voltage 220 VAC. Mounting PCB w / Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation class F. |
Global Components & Controls |
3581 |
G901AS-AC220-1NIL |
Relay. Coil voltage 220 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
3582 |
G901AS-AC220-NIL2 |
Relay. Coil voltage 220 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
3583 |
G901AS-AC220-NILNIL |
Relay. Coil voltage 220 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation STD. Class B. |
Global Components & Controls |
3584 |
G901AS-AC24-12 |
Relay. Coil voltage 24 VAC. Mounting PCB w / Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation class F. |
Global Components & Controls |
3585 |
G901AS-AC24-1NIL |
Relay. Coil voltage 24 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
3586 |
G901AS-AC24-NIL2 |
Relay. Coil voltage 24 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
3587 |
G901AS-AC24-NILNIL |
Relay. Coil voltage 24 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation STD. Class B. |
Global Components & Controls |
3588 |
G901AS-AC48-12 |
Relay. Coil voltage 48 VAC. Mounting PCB w / Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation class F. |
Global Components & Controls |
3589 |
G901AS-AC48-1NIL |
Relay. Coil voltage 48 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
3590 |
G901AS-AC48-NIL2 |
Relay. Coil voltage 48 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
3591 |
G901AS-AC48-NILNIL |
Relay. Coil voltage 48 VAC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation STD. Class B. |
Global Components & Controls |
3592 |
G901AS-DC110-12 |
Relay. Coil voltage 110 VDC. Mounting PCB w / Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation class F. |
Global Components & Controls |
3593 |
G901AS-DC110-1NIL |
Relay. Coil voltage 110 VDC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
3594 |
G901AS-DC110-NIL2 |
Relay. Coil voltage 110 VDC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
3595 |
G901AS-DC110-NILNIL |
Relay. Coil voltage 110 VDC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
3596 |
G901AS-DC12-12 |
Relay. Coil voltage 12 VDC. Mounting PCB w / Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation class F. |
Global Components & Controls |
3597 |
G901AS-DC12-1NIL |
Relay. Coil voltage 12 VDC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
3598 |
G901AS-DC12-NIL2 |
Relay. Coil voltage 12 VDC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
3599 |
G901AS-DC12-NILNIL |
Relay. Coil voltage 12 VDC. Mounting PCB w/ Top QC. Contact form A. Covering sealed. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
3600 |
G901AS-DC15-12 |
Relay. Coil voltage 15 VDC. Mounting PCB w / Top QC. Contact form A. Covering sealed. Spacing UL873. Insulation class F. |
Global Components & Controls |
| | | |