No. |
Part Name |
Description |
Manufacturer |
5731 |
G90NILBS-DC110-NILNIL |
Relay. Coil voltage 110 VDC. Mounting PCB. Contact form B. Covering sealed. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
5732 |
G90NILCD-AC110-12 |
Relay. Coil voltage 110 VAC. Mounting PCB. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
5733 |
G90NILCD-AC110-1NIL |
Relay. Coil voltage 110 VAC. Mounting PCB. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
5734 |
G90NILCD-AC110-NIL2 |
Relay. Coil voltage 110 VAC. Mounting PCB . Contact form C. Covering dust cover. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
5735 |
G90NILCD-AC110-NILNIL |
Relay. Coil voltage 110 VAC. Mounting PCB. Contact form C. Covering dust cover. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
5736 |
G90NILCD-AC220-12 |
Relay. Coil voltage 220 VAC. Mounting PCB. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
5737 |
G90NILCD-AC220-1NIL |
Relay. Coil voltage 220 VAC. Mounting PCB. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
5738 |
G90NILCD-AC220-NIL2 |
Relay. Coil voltage 220 VAC. Mounting PCB . Contact form C. Covering dust cover. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
5739 |
G90NILCD-AC220-NILNIL |
Relay. Coil voltage 220 VAC. Mounting PCB. Contact form C. Covering dust cover. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
5740 |
G90NILCD-DC110-12 |
Relay. Coil voltage 110 VDC. Mounting PCB. Contact form C. Covering dust cover. Spacing UL873. Insulation class F. |
Global Components & Controls |
5741 |
G90NILCD-DC110-1NIL |
Relay. Coil voltage 110 VDC. Mounting PCB. Contact form C. Covering dust cover. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
5742 |
G90NILCD-DC110-NIL2 |
Relay. Coil voltage 110 VDC. Mounting PCB. Contact form C. Covering dust cover. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
5743 |
G90NILCD-DC110-NILNIL |
Relay. Coil voltage 110 VDC. Mounting PCB. Contact form C. Covering dust cover. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
5744 |
G90NILCO-AC110-12 |
Relay. Coil voltage 110 VAC. Mounting PCB. Contact form C. Covering open frame. Spacing UL873. Insulation class F. |
Global Components & Controls |
5745 |
G90NILCO-AC110-1NIL |
Relay. Coil voltage 110 VAC. Mounting PCB. Contact form C. Covering open frame. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
5746 |
G90NILCO-AC110-NIL2 |
Relay. Coil voltage 110 VAC. Mounting PCB. Contact form C. Covering open frame. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
5747 |
G90NILCO-AC110-NILNIL |
Relay. Coil voltage 110 VAC. Mounting PCB. Contact form C. Covering open frame. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
5748 |
G90NILCO-AC220-12 |
Relay. Coil voltage 220 VAC. Mounting PCB. Contact form C. Covering open frame. Spacing UL873. Insulation class F. |
Global Components & Controls |
5749 |
G90NILCO-AC220-1NIL |
Relay. Coil voltage 220 VAC. Mounting PCB. Contact form C. Covering open frame. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
5750 |
G90NILCO-AC220-NIL2 |
Relay. Coil voltage 220 VAC. Mounting PCB. Contact form C. Covering open frame. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
5751 |
G90NILCO-AC220-NILNIL |
Relay. Coil voltage 220 VAC. Mounting PCB. Contact form C. Covering open frame. Spacing Std UL508. Insulation STD.classB. |
Global Components & Controls |
5752 |
G90NILCO-DC110-12 |
Relay. Coil voltage 110 VDC. Mounting PCB. Contact form C. Covering open frame. Spacing UL873. Insulation class F. |
Global Components & Controls |
5753 |
G90NILCO-DC110-1NIL |
Relay. Coil voltage 110 VDC. Mounting PCB. Contact form C. Covering open frame. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
5754 |
G90NILCO-DC110-NIL2 |
Relay. Coil voltage 110 VDC. Mounting PCB. Contact form C. Covering open frame. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
5755 |
G90NILCO-DC110-NILNIL |
Relay. Coil voltage 110 VDC. Mounting PCB. Contact form C. Covering open frame. Spacing StdUL508. Insulation STD.classB. |
Global Components & Controls |
5756 |
G90NILCS-AC110-12 |
Relay. Coil voltage 110 VAC. Mounting PCB. Contact form C. Covering sealed. Spacing UL873. Insulation class F. |
Global Components & Controls |
5757 |
G90NILCS-AC110-1NIL |
Relay. Coil voltage 110 VAC. Mounting PCB. Contact form C. Covering sealed. Spacing UL873. Insulation Std. Class B. |
Global Components & Controls |
5758 |
G90NILCS-AC110-NIL2 |
Relay. Coil voltage 110 VAC. Mounting PCB . Contact form C. Covering sealed. Spacing STD UL508. Insulation class F. |
Global Components & Controls |
5759 |
G90NILCS-AC110-NILNIL |
Relay. Coil voltage 110 VAC. Mounting PCB. Contact form C. Covering sealed. Spacing STD UL508. Insulation STD. Class B. |
Global Components & Controls |
5760 |
G90NILCS-AC220-12 |
Relay. Coil voltage 220 VAC. Mounting PCB. Contact form C. Covering sealed. Spacing UL873. Insulation class F. |
Global Components & Controls |
| | | |